The Main Eco Elite Combi is a fully automatic, gas-fired, wall-mounted condensing combination boiler, designed for efficient heating and hot water delivery within your home.
Boiler Overview and Key Features
The Main Eco Elite Combi is engineered as a room-sealed, fan-assisted unit, ensuring safe and efficient operation. This boiler boasts fully automatic functionality, simplifying its use for homeowners. It’s designed to deliver both central heating and domestic hot water on demand, making it a versatile choice for various household sizes.
Key features include condensing technology, maximizing efficiency and reducing gas consumption. The boiler is compatible with a range of flue systems, offering flexibility during installation. Furthermore, it’s designed for easy maintenance access, streamlining servicing procedures. The Eco Elite models, such as the 25 and 30 ErP versions (G.C. No 47 467 12 and respective numbers), offer varying output levels to suit different heating demands.
ErP Compliance and Energy Efficiency
The Main Eco Elite Combi boilers are designed to meet stringent ErP (Energy-related Products) directives, ensuring high levels of energy efficiency and reduced environmental impact. Condensing technology is central to this, recovering latent heat from flue gases that would otherwise be wasted.
These boilers achieve impressive efficiency ratings, contributing to lower heating bills and a reduced carbon footprint. The ErP compliance details, specific to models like the Main Eco Elite 25 Combi ErP and 30 Combi ErP, are clearly indicated (G.C. No 47 467 12 and respective numbers). This compliance signifies adherence to European standards for energy performance, promoting sustainable heating solutions for homes.

Safety Precautions

Always ensure proper ventilation and install a carbon monoxide detector, as the Main Eco Elite is a gas appliance requiring careful handling and maintenance.
General Safety Guidelines
Prior to installation and servicing, thoroughly read the entire Main Eco Elite boiler manual to understand all safety precautions and operational procedures. This boiler is designed for indoor use only and must be installed by a qualified and competent gas safe registered engineer.
Ensure the boiler is correctly positioned and securely mounted on a suitable wall, adhering to the guidelines outlined in the installation section. Never attempt to modify the boiler or its components, as this could compromise safety and void the warranty. Regularly inspect the flue for any signs of damage or blockage, and address any issues immediately.
Keep the surrounding area clear of flammable materials and ensure adequate ventilation. Always turn off the gas and electricity supply before performing any maintenance or repairs. Familiarize yourself with the location of the emergency shut-off valves.
Carbon Monoxide Risks and Detection
Carbon Monoxide (CO) is a colorless, odorless, and highly poisonous gas produced by incomplete combustion. A faulty Main Eco Elite boiler can potentially release CO, posing a severe health risk to occupants. It is crucial to install a certified CO detector in a central location near the boiler, following the manufacturer’s instructions.
Regularly test the CO detector to ensure it is functioning correctly. Be aware of the symptoms of CO poisoning, which include headache, dizziness, nausea, and confusion. If you suspect CO poisoning, immediately evacuate the premises and call emergency services.
Never ignore any unusual smells or noises coming from the boiler. Ensure the flue is regularly inspected and maintained to prevent CO buildup. Proper ventilation is also essential for safe operation.

Boiler Installation
The Main Eco Elite Combi is designed for wall mounting and requires proper gas and water connections, adhering to all relevant safety regulations and guidelines.
Wall Mounting and Positioning
Proper wall mounting is crucial for the safe and efficient operation of the Main Eco Elite Combi boiler. The unit must be securely fixed to a structurally sound wall, capable of supporting its weight when fully loaded with water. Ensure sufficient space around the boiler for servicing and maintenance access, as outlined in the installation guide.
The boiler is designed to be mounted on the rear wall plate, ensuring a stable and level installation. Verify the wall is flat and free from obstructions before proceeding. Consider the proximity to gas and water services to minimize pipe runs and potential heat loss. Adequate ventilation is also essential; avoid installing the boiler in confined spaces without proper airflow. Always consult a qualified Gas Safe registered engineer for installation.
Gas and Water Connections
Gas and water connections for the Main Eco Elite Combi boiler require strict adherence to safety regulations and manufacturer’s instructions. A qualified Gas Safe registered engineer must perform all gas connections, ensuring they are leak-tight and comply with current standards. The gas supply must be at the correct pressure, as specified in the technical data.

Water connections should be made using appropriate flexible hoses and fittings, ensuring they are securely tightened to prevent leaks. Cold water supply must meet the boiler’s flow rate requirements. Proper sealing and isolation valves are essential for maintenance and emergency shut-off. Always purge the gas line before connecting to the boiler. Incorrect connections can compromise safety and boiler performance.

Boiler Operation
The Main Eco Elite is a fully automatic system boiler, offering efficient heating and hot water; operation is managed via its intuitive control panel interface.
Control Panel Explanation
The Main Eco Elite boiler’s control panel provides a user-friendly interface for managing your heating and hot water. Key features include a digital display showing the current system temperature and any error codes that may arise. Buttons allow for adjusting the desired room temperature and setting hot water schedules.

The panel also displays the boiler’s operating status – whether it’s actively heating, providing hot water, or in standby mode. Familiarize yourself with the indicator lights, which signal important information like flame detection and water pressure. Understanding these indicators is crucial for basic troubleshooting. The control panel enables efficient and personalized control over your home comfort, ensuring optimal performance and energy savings. Refer to the full manual for detailed explanations of all functions.
Setting Temperature and Hot Water
Adjusting the room temperature on your Main Eco Elite boiler is straightforward using the control panel’s up and down buttons. The display will show your selected temperature, allowing for precise control of your home’s heating. For hot water, you can typically choose between comfort, standard, and eco modes, influencing the speed and temperature of hot water delivery.
Many models allow scheduling hot water to coincide with peak usage times, maximizing efficiency. Explore the panel’s settings to establish a personalized heating schedule that suits your lifestyle. Remember to consider energy conservation when setting temperatures and schedules; Refer to the comprehensive manual for detailed instructions and advanced features related to temperature and hot water control.

Troubleshooting Common Issues
Addressing problems like no heating or low pressure is often possible by consulting the Main Eco Elite manual for guidance and potential solutions.
No Heating or Hot Water
If your Main Eco Elite boiler isn’t providing heating or hot water, first check the thermostat settings and ensure it’s calling for heat. Verify the boiler’s power supply and that the pilot light (if applicable) is lit. Low gas pressure can also be a culprit; check if other gas appliances are working.
Consult the manual for specific error codes displayed on the control panel, as these pinpoint the issue. A common cause is air in the system, requiring bleeding of radiators. If the problem persists, examine the diverter valve – a faulty valve can prevent hot water flow. Remember to always prioritize safety and consult a qualified engineer if you’re uncomfortable performing any checks or repairs yourself. The manual provides detailed diagrams and troubleshooting steps.
Low Pressure Problems
Low pressure on your Main Eco Elite boiler often indicates a water leak somewhere within the central heating system. Before attempting to repressurize, carefully inspect all visible pipes, radiators, and the boiler itself for any signs of dampness or leaks. The manual details the correct pressure range for your specific model – typically between 1 and 1.5 bar.
To repressurize, follow the instructions in the manual, usually involving opening the filling loop valve. Monitor the pressure gauge closely during this process. Repeatedly low pressure suggests a significant leak requiring professional attention. Do not exceed the maximum pressure, as this can damage the system. Ignoring low pressure can lead to reduced heating efficiency and potential boiler failure; consult the manual for detailed guidance.

Boiler Maintenance
Regular servicing, as outlined in the manual, is crucial for optimal performance and longevity of your Main Eco Elite boiler, ensuring efficiency and safety.
Regular Servicing Requirements
To maintain the efficiency and safety of your Main Eco Elite boiler, annual servicing by a qualified Gas Safe registered engineer is absolutely essential. This service involves a comprehensive inspection of all components, including the burner, heat exchanger, flue, and gas connections.
The engineer will check for any signs of corrosion, leaks, or damage, and will clean the boiler as necessary. Proper servicing ensures optimal combustion, minimizing carbon monoxide risks and maximizing energy efficiency. The manual details the importance of logbook completion after each service, documenting all work carried out. Ignoring regular servicing can invalidate your warranty and potentially lead to dangerous operating conditions. Adhering to the recommended service schedule protects your investment and ensures peace of mind.
Descaling Procedures
Over time, scale buildup within the Main Eco Elite boiler’s heat exchanger can reduce efficiency and potentially cause damage. Regular descaling is therefore recommended, particularly in areas with hard water. The manual outlines a specific descaling procedure utilizing a suitable, approved chemical descaler.
Always follow the descaler manufacturer’s instructions carefully, and ensure the boiler is isolated from the gas and electricity supply before commencing. The descaling process involves circulating the descaling solution through the boiler for a specified duration, followed by a thorough flush with clean water. Incorrect descaling can cause corrosion; therefore, professional assistance is advised if you are unsure. Regular descaling maintains optimal performance and extends the boiler’s lifespan.

Technical Specifications
The Main Eco Elite series includes 25 and 30 Combi ErP models, identified by G.C. Nos 47 467 12 and corresponding details within the manual.
Main Eco Elite 25 Combi ErP Details
The Main Eco Elite 25 Combi ErP boiler is a highly efficient condensing combination boiler, suitable for homes with moderate heating and hot water demands. This model, identified by G.C. No 47 467 12, delivers a rated output designed to effectively heat typical family homes.
As a fully automatic, gas-fired unit, it offers room-sealed operation with fan assistance, ensuring safe and efficient combustion. The ErP rating signifies its adherence to European energy efficiency standards, promising reduced energy consumption and lower utility bills. Detailed specifications, including dimensions, weight, and gas connection details, are comprehensively outlined within the official installation and service manual.
Users should consult the manual for precise information regarding flow rates, gas consumption, and other critical performance characteristics of this specific model.
Main Eco Elite 30 Combi ErP Details
The Main Eco Elite 30 Combi ErP boiler is a powerful and efficient condensing combination boiler, ideal for larger homes or those with higher hot water requirements. Identified by G.C. No 47 467 12, this model provides an increased heating output compared to the 25 Combi version, ensuring consistent warmth even during peak demand.
Like its counterpart, it’s a fully automatic, gas-fired unit featuring room-sealed operation and fan assistance for safe and efficient combustion. The ErP rating confirms its compliance with European energy efficiency standards, contributing to lower energy bills and a reduced carbon footprint. The comprehensive installation and service manual details all technical specifications.
Refer to the manual for precise data on flow rates, gas consumption, and other vital performance metrics specific to this 30 Combi ErP model.